Capillary Moisture Removal System Technical Specifications
The system shall be an ultrasonic wave transmitter controlled by a compact electronic control system measuring 342x194x135 mm, operating at 220 Volts, 11 Watts power, with a signal frequency of 141 kHz.
Drying electrodes shall be hexagonal-section rods made of aluminum, measuring 6x90 mm.
Measurement electrodes shall be insulated hexagonal-section rods made of aluminum, measuring 6x60, 6x70, 6x90, 6x120, or 6x150 mm.
The ferrite antenna shall function as an electromagnetic sensor between the ground and the system, operating at 141 kHz signal frequency, and shall be a fully plastic-protected wound coil.